36V Lithium-Ion Battery Maximum Charging Voltage & Cut-Off Voltage
Pages 정보

본문
"36V Lithium-Ion Battery's Maximum Charging Voltage & Cut-Off Voltage"
-
Maximum Charging Voltage (Full Charge Voltage)
For a typical 36V battery (10S lithium-ion cells):
-
Maximum Charging Voltage = 42.0V (4.2V per cell × 10 cells)
-
A 42V charger is required when charging.
-
-
Cut-Off Voltage (Minimum Discharge Voltage)
-
Safe Discharge Limit: About 30V–32V (3.0V–3.2V per cell)
-
Complete Discharge Voltage (Danger Level): Below 28V (Below 2.8V per cell → Possible battery damage)
-
-
Recommended Charging and Discharging Range (Battery Lifespan Tip)
-
Optimal Charging Range: 40V–41V
-
Safe Discharge Range: Charge when the battery is at 30% or higher (Maintain above 32V)
Charging the battery to 100% frequently or discharging it below 30V can significantly shorten the battery lifespan. The best practice is to charge up to 40V (about 80%) and avoid discharging below 32V (about 30%) for optimal battery management.
-
- Prev48V Lithium-Ion Battery Maximum Charging Voltage & Cut-Off Voltage 25.03.28
- Next"Efficient Lithium-Ion Battery Management (Electric Bicycles, Electric Scooters, etc.)" 25.03.28